Portable Multi-Gas Analyzer NDIR-GFC MIR 9000PThe MIR 9000P belongs to the new generation of ENVEA gas monitors, showcasing eco-design, IoT and on board intelligence.
It measures simultaneously 8 gases – NOx, SO2, CO, CO2, CH4, N2O, O2 and residual H2O – and uses the non-dispersive infrared method (NDIR-GFC) with gas filter correlation. O2 is measured by a built-in SRM paramagnetic sensor.
The analyzer has been designed to meet the specific needs of on-site regulatory measurement providing superior mobility, robustness, accuracy and compliance. All this makes up for a unique gas emission monitor offering high productivity and low operational cost.
Features & Benefits
INCREASED MOBILITY & PRODUCTIVITY
- Lightweight (15 kg/33 lbs), compact and extra resistant transport case
- Standby mode guarantees the instrument is operational at any time
ROBUST DESIGN
- Extended operating temperature ranges
- High protection (IP 44) against water splashing from any direction
STAY CONNECTED & GET ON WITH OTHER TASKS
- Remote access to full operation thanks to ENVEA Connect™ App and proprietary WiFi
- Smartphone alerts and notifications
ONE CLICK OPERATIONS
- Integrated user guidance and shortcuts to key functions: calibrations, span check, zero, etc.
- Secured user management
QUICK INSTALLATION
- Warm-up time: 30 min maximum
- Robust gas connectors
- Self-adaptive measuring scales
- Compatible with most sampling systems on the market
PREPARE REPORT ELEMENTS WHILE ON SITE
- Direct access to real-time and stored data ; time frame selection to generate graphs
- All data can be saved on USB memory stick
MAXIMIZED UPTIME OF THE ANALYZER
- Turn-up lid designed for quick access to operational modules and easy maintenance
- Modular design and Plug & Play parts (O2 probe, NOx converter, protection filter, etc.)
- 8 simultaneous parameters : NOx, SO2, CO, CO2,CH4 and N2O, O2 and residual H2O – All-in-one case design for easy transport/storage
- Lightweight (15 kg, 33 lbs), compact and extra resistant transport case
- Standby mode guarantees the instrument is operational at any time
- Analyzer designed to operate case closed or open.
- Remote access to full operation thanks to ENVEA Connect™ App and proprietary WiFi, smartphone alerts & notifications, IoT ready
- Warm-up time : 30 min maximum. Compatible with most sampling systems on the market, fast gas connectors, self adapting gas scales
- Secured multi-user management, shortcuts to key functions (zero, span check, calibration…)
- Front side indicator provides key status info to the user
- Redundant and secured data back-up
- Easy and reduced maintenance : modular design and Plug & Play parts, turn-up lid designed for quick access to operational elements
Main applications
- Regulatory and periodic stack emission monitoring for industrial combustion sites, boilers, etc.
Measuring Ranges |
NOx as NO (after NOx converter) |
0/70*/2000*/3300 mg/Nm3 0-50/1500/2500 ppm |
NOx as NO2 (after NOx converter) |
0/107*/3100*/5000 mg/Nm3 0/50*/1500*/2500 ppm |
SO2 |
0/143*/2000*/8600 mg/Nm3 0/50*/700*/3000 ppm |
CO |
0/70*/3000*/8000 mg/Nm3 0/60*/2500*/6500 ppm |
CO2 |
0-20/30% vol. |
N2O |
0/50/150*/450*/980 mg/Nm3 0/25/75*/225*/500 ppm |
CH4 |
0/70/140/400/5000 ppm 0/50/100/300/3600 mg/Nm3 |
O2 |
0-10/25% vol. measured by a built-in paramagnetic sensor |
Residual H2O |
0-2% vol. |
*certified range
Technical Specifications |
QAL1 to EN 15267-4 certified |
YES |
US EPA compliance |
YES |
Sampling technology |
Cold/Dry Extraction (gas cooler) |
Sample transfert |
non heated polytube / heated sampling line |
back flush function |
N/A |
span injection |
YES |
Built-In O2 sensor |
YES |
Built-In NOx oven |
YES |
Serial link communication |
3 x USB ports type A: 2.0 (compatible 3.0) 1 x RJ45 (MODBUS TCP, MODBUS RTU (dongle) UDP Protocol) |
Other Communication |
WiFi (via USB) |
INPUTS/OUTPUTS module |
8 non-isolated analog outputs (0-1 V, 0-10 V, 0-20 mA, or 4-20 mA), with common ground and user programmable scales 8 non-isolated analog inputs 0-2.5 V 8 isolated digital inputs 12 digital outputs by potential free relay |
Optional cable for analog INPUTS |
Dynamic 250 mV or 10V (only one input can be used at once) |
Dimensions (mm) |
641 x 209 x 393mm (WxDxH) |
Approvals & certifications
- QAL1 certification by the TÜV according to EN 15267-1, EN 15267-2 and EN 15267-4. Download the TÜV certificate: 0000074636
- Compliant with EN 15267-4
- Air quality – Certification of automated measuring systems – Part 4: Performance criteria and test procedures for automated measuring systems for periodic measurements of emissions from stationary sources
- Compliant with US EPA
Documentation
envea_mir9000p-stack-emission-portable-multigas-analyzer_en
envea_catalogue_cems_emission-monitoring_en
ENVEA_Process_Catalogue_EN